Mahr – Millimar 832 PE/F1 Digital/Analog Air Gauge

$0.00

Description

Mahr Federal
Millimar 832 PE/F1 Digital/Analog Air Gauge

 Digital and analog display in one unit.

  • Large, high contrast digital display of the exact deviation from zero
  • Analog display of measurement related information
  • With its fixed ratio and controlled compressed air supply, the digital Dimensionair is a sturdy, reliable system for manufacturing environments.
  • Only one standard needed for zero offset; the instrument is precalibrated for the correct ratio
  • Measuring ranges and resolutions for almost all measuring applications (including measuring equipment with 2, 3, 4 and 6 nozzles, air sensors and nozzle measuring probes, etc.)
  • Suitable for dynamic measurement
  • RS-232 output for communication with a data storage device, computer or printer, for statistical process control
  • Master deviation – improved measurement with even more accurate automatic zero offset.

Technical data

Order no. Product type Display Range of digital display µm Range of digital display inch Resolution µm Graduation mm Graduation value inch Tolerance display Compatibility Dynamic functions Statistical functions Response time digital display Error limit Data interface Control outputs Analogue output Energy supply Operating temperature Min Operating temperature Max Product weight
2004100
832 PE/F1
Display mode A (or A and B for 2 channel models only)
± 80 / ± 40 / ± 20
± .003″ / ± .0015″ / ± .00075″
0,2
4 / 2 / 1
150 µ” / 75 µ” / 38 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004101
832 PE/F1
Display mode A (or A and B for 2 channel models only)
± 80 / ± 40 / ± 20
± .003″ / ± .0015″ / ± .00075″
0,2
4 / 2 / 1
150 µ” / 75 µ” / 38 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004102
832 PE/F1
Display mode A (or A and B for 2 channel models only)
± 80 / ± 40 / ± 20
± .003″ / ± .0015″ / ± .00075″
0,2
4 / 2 / 1
150 µ” / 75 µ” / 38 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004103
832 PE/F1
Display mode A (or A and B for 2 channel models only)
± 8 / ± 4
± .0003″ / ± .00015″
0,1
0,4 / 0,2
15 µ” / 8 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004104
832 PE/F1
Display mode A (or A and B for 2 channel models only)
± 8 / ± 4
± .0003″ / ± .00015″
0,1
0,4 / 0,2
15 µ” / 8 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004105
832 PE/F1
Display mode A (or A and B for 2 channel models only)
± 8 / ± 4
± .0003″ / ± .00015″
0,1
0,4 / 0,2
15 µ” / 8 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004106
832 PE/F2
Display mode A (or A and B for 2 channel models only)
± 80 / ± 40 / ± 20
± .003″ / ± .0015″ / ± .00075″
0,2
4 / 2 / 1
150 µ” / 75 µ” / 38 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004107
832 PE/F2
Display mode A (or A and B for 2 channel models only)
± 80 / ± 40 / ± 20
± .003″ / ± .0015″ / ± .00075″
0,2
4 / 2 / 1
150 µ” / 75 µ” / 38 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004108
832 PE/F2
Display mode A (or A and B for 2 channel models only)
± 80 / ± 40 / ± 20
± .003″ / ± .0015″ / ± .00075″
0,2
4 / 2 / 1
150 µ” / 75 µ” / 38 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004109
832 PE/F2
Display mode A (or A and B for 2 channel models only)
± 8 / ± 4
± .0003″ / ± .00015″
0,1
0,4 / 0,2
15 µ” / 8 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004110
832 PE/F2
Display mode A (or A and B for 2 channel models only)
± 8 / ± 4
± .0003″ / ± .00015″
0,1
0,4 / 0,2
15 µ” / 8 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004111
832 PE/F2
Display mode A (or A and B for 2 channel models only)
± 8 / ± 4
± .0003″ / ± .00015″
0,1
0,4 / 0,2
15 µ” / 8 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
110 V / 60 Hz / Power source
5 °C
35 °C
5 kg
2004112
832 PE/F1
Display mode A (or A and B for 2 channel models only)
± 80 / ± 40 / ± 20
± .003″ / ± .0015″ / ± .00075″
0,2
4 / 2 / 1
150 µ” / 75 µ” / 38 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range for signal ±A, ±B
230 V / 50 Hz / Power source
5 °C
35 °C
5 kg
2004113
832 PE/F1
Display mode A (or A and B for 2 channel models only)
± 80 / ± 40 / ± 20
± .003″ / ± .0015″ / ± .00075″
0,2
4 / 2 / 1
150 µ” / 75 µ” / 38 µ”
5 LEDs
Federal
Max, Min, Max-Min
Actual value, nominal value
0.43 s
+/- 1 digit
RS232C
5 TTL optocoupler outputs
±5 VDC at maximum amplitude of the selected measuring range

Go to Top