Mitutoyo – MF Series 176, Motorized Type Measuring Microscope

$0.00

Category: SKU: SKU 203

Description

 

MITUTOYO AMERICA
MF Series 176, Motorized Type Measuring Microscope

  
Features
  • Motorized model of the MF Series. The X-Y- and Z-axes are motorized, and the stage can be operated using a remote box.
  • Using the optional Vision Unit enables the image AF function.
  • Illumination unit (reflected/transmitted) can be selected from a high-intensity LED or halogen bulb (required).
  • Variable aperture diaphragm (reflected/ transmitted) allows observation measurement while suppressing light diffraction.
  • A wide variety of optional accessories including various digital CCD cameras are offered.
  • ML series, high-NA objectives that are specially designed for the MF series. (long working distance type)
  • High-magnification observation up to 2000X.
  • MF-G2017D the binocular tube (eyepiece) and illumination unit are optional accessories.

*1:  Vision Unit and an image AF cable are separately required.
*2:  Measuring method complies with JIS B1753.

 
Model MF-G2017D MF-G3017D MF-G4020D
Order No. 176-781A 176–782A 176-783A
Observation image BF (Bright field)/Erect image BF (Bright field)/Erect image BF (Bright field)/Erect image
Eyepiece Diopter adjustment 10X (field number: 24), 15X, 20X
Note: Monocular unit: a 10X eyepiece (standard accessory), Binocular tube: two 10X eyepieces (standard accessory)
10X (field number: 24), 15X, 20X
Note: Monocular unit: a 10X eyepiece (standard accessory), Binocular tube: two 10X eyepieces (standard accessory)
10X (field number: 24), 15X, 20X
Note: Monocular unit: a 10X eyepiece (standard accessory), Binocular tube: two 10X eyepieces (standard accessory)
Objective lens ML series 3X objective lens (standard accessory), 1X, 5X, 10X, 20X, 50X, 100X

ML series 3X objective lens (standard accessory), 1X, 5X, 10X, 20X, 50X, 100X

ML series 3X objective lens (standard accessory), 1X, 5X, 10X, 20X, 50X, 100X

Illumination

(one of two options must be selected

LED illumination unit:

Transmitted illumination: Telecentric system, Built-in aperture diaphragm, White LED light source, step less light intensity control, With cooling fan

Reflected illumination: Koehler illumination, Variable aperture diaphragm mechanism, White LED light source, step less light intensity control

Control unit: Power ON/OFF switch (main switch), 100 – 240V AC power input connector

Halogen illumination unit:

Transmitted illumination: Telecentric system, Built-in aperture diaphragm, Halogen bulb (12V, 50W), step less light intensity control, With cooling fan

Reflected illumination: Koehler illumination, Variable aperture diaphragm mechanism, Halogen bulb (12V, 50W), step less light intensity control, With cooling fan

Control unit: Power ON/OFF switch (main switch), 100 – 240V AC power input connector

LED illumination unit:

Transmitted illumination: Telecentric system, Built-in aperture diaphragm, White LED light source, step less light intensity control, With cooling fan

Reflected illumination: Koehler illumination, Variable aperture diaphragm mechanism, White LED light source, step less light intensity control

Control unit: Power ON/OFF switch (main switch), 100 – 240V AC power input connector

Halogen illumination unit:

Transmitted illumination: Telecentric system, Built-in aperture diaphragm, Halogen bulb (12V, 50W), step less light intensity control, With cooling fan

Reflected illumination: Koehler illumination, Variable aperture diaphragm mechanism, Halogen bulb (12V, 50W), step less light intensity control, With cooling fan

Control unit: Power ON/OFF switch (main switch), 100 – 240V AC power input connector

LED illumination unit:

Transmitted illumination: Telecentric system, Built-in aperture diaphragm, White LED light source, step less light intensity control, With cooling fan

Reflected illumination: Koehler illumination, Variable aperture diaphragm mechanism, White LED light source, step less light intensity control

Control unit: Power ON/OFF switch (main switch), 100 – 240V AC power input connector

Halogen illumination unit:

Transmitted illumination: Telecentric system, Built-in aperture diaphragm, Halogen bulb (12V, 50W), step less light intensity control, With cooling fan

Reflected illumination: Koehler illumination, Variable aperture diaphragm mechanism, Halogen bulb (12V, 50W), step less light intensity control, With cooling fan

Control unit: Power ON/OFF switch (main switch), 100 – 240V AC power input connector

XY-axis Vision measuring range 200x170mm 300x170mm 400x200mm
Z-axiz measuring range 220mm 220mm 220mm

Measuring accuracy *2

(When no load is put on the X or Y axis)

(2.2+0.02L)µm L: Measuring length (mm) (2.2+0.02L)µm L: Measuring length (mm) (2.2+0.02L)µm L: Measuring length (mm)
Digitial counter Resolution 1/0.5/0.1µm .0001”/.00005”/.00001” switchable 1/0.5/0.1µm .0001”/.00005”/.00001” switchable 1/0.5/0.1µm .0001”/.00005”/.00001” switchable
 


WARRANTY:    1-year warranty on parts and labor.

INSTALLATION:  We provide setup, installation, onsite calibration and training of your operators at your facitily.